Planning
Planning a dental simulation lab: the checklist
From the number of phantom head workstations to the cable route inside the treatment unit — eight points to settle before a tender goes out.
Basis for planning
What planning a dental simulation lab settles
Planning a dental simulation lab settles three things before any equipment is ordered: the number of phantom head workstations, the image sources at each individual position, and the routes by which their image reaches all the other monitors.
A laboratory of this kind is planned together with the manufacturer of the treatment units. The plan therefore takes shape in two places at once: the units determine where a monitor can hang and where a cable can run, and the transmission system determines which image arrives there.
The eight points on this page follow the order in which they come up in conversation — first the room and the positions, then the sources, then the routes and the control. Where a detail has yet to be settled internally, the floor plan is enough for a first quotation; the rest can follow.
Checklist
Eight points to a specification
Each point ends with the details that have to come from your institution. Once they are together, the tender can go out.
Count the phantom head workstations
Count every position that carries a monitor — including the positions of a later construction phase. That number determines the layout: a star reaches up to 100 workstations via satellites, a ring up to 50 student positions.
- Positions in the classroom with their own monitor
- Positions in adjacent rooms that should be included
- Positions from a later construction phase
Define the instructor position
The instructor position is the point from which the system is operated. Whether it holds a complete treatment unit or only a desk with a computer changes the number of inputs at that point — and the question of whether a second position is provided for an assistant.
- Treatment unit at the instructor position or a desk
- Second position for an assistant or a guest lecturer
- Large display in addition to the workstation monitors
Name the image sources at each position
A phantom head workstation often carries several image sources side by side: a computer, an intraoral camera and a microscope camera. Every source that should be shown to the class needs an input of its own; which source is planned at which position determines how the box is equipped.
- Computer at the position — PC or thin client
- Intraoral camera on the treatment unit
- Camera output on the microscope
- Visualiser or document camera in the room
Check sightlines and monitor position
The monitor at the workstation takes over the sightline that otherwise runs across the room to the instructor. Where it hangs decides whether the student can see it without lifting their head out of the working field. Size, height and swivel range therefore belong in the plan before the mounts are ordered.
- Monitor size and height above the treatment unit
- Swivel arm or fixed mount
- No glare from the operating light
- Sightline to the instructor position that should stay clear
Settle the cable routes
Picture and sound run over dedicated cabling, not over the building's data network. Each line runs from the workstation to the central unit, through a raised floor, a cable duct or a ceiling suspension; which channels the treatment units bring with them is clarified by their manufacturer. Over long runs, extenders and repeaters recondition the video signal.
- Raised floor, floor box or ceiling route
- Free channels inside the treatment units
- Location of the central unit: in the room or in a technical cabinet
- Runs on which a repeater is provided
Connect a live treatment room
A treatment room can be connected to the same lab and switched as a source like any workstation. What needs settling is the line to it, the sources in the room itself and the question of who starts the transmission — the instructor in the lab or the staff at the chair.
- Route and length between the treatment room and the lab
- Cameras and microscope in the treatment room
- Control in the lab, at the chair or in both places
- Sound from the treatment room into the classroom
Choose the control
The system is operated from a touchscreen, a system keyboard, a tablet or an existing media control system over RS232. The tablet connects to the system directly over Bluetooth and joins no network; the system keyboard needs no power supply of its own and its key layout can be matched to the seating plan of the room.
- Fixed control unit at the instructor position
- Mobile control during the class
- Existing media control system to be integrated
- Key labelling following the seating plan
Provide for extension
Extensions concern the cabling first, not the equipment. Whether positions, a second classroom or a further treatment room are added later therefore belongs in the first discussion: spare lines, empty conduits and room in the central unit can then be planned in from the start.
- Planned second construction phase
- Spare lines and empty conduits
- Room in the central unit for further modules
- Second classroom to be linked later
Tendering
Details for the specification
These lines describe the alphadidact® Digital transmission system that connects the positions. They can be taken into a specification unchanged.
- System layout
- Star up to 100 workstations, ring up to 50 student positions
- Connection between the boxes
- DVI-D (HDMI signal, with audio)
- Type of transmission
- Uncompressed — no encoding, no buffering
- Sources per workstation
- PC or thin client, intraoral camera, microscope camera
- Long runs
- Extenders and repeaters on DVI, without a network
- Building data network
- Not involved; picture and sound run over dedicated cabling
- Software at the workstations
- None — the function sits in the boxes
- Control
- Touchscreen, system keyboard, tablet over Bluetooth, RS232
- Warranty
- 3 years, extendable to 5 years
- Development and manufacture
- Heusenstamm near Frankfurt
Details of treatment units, monitors and cameras come from their respective manufacturer; this table describes the transmission system alone.
Case studies
Laboratories planned this way
Each report states the number of simulation positions, the sources connected and the control used — useful as a comparison for your own planning.

1 March 2025
Hong Bang International University, Vietnam
The Hong Bang International University (HIU) in Vietnam is modernising its dental education with digital systems. Together with MEDENT, a leading provider of …

24 October 2024
Arab Academy New Alamein City, Egypt
The Arab Academy for Science, Technology, and Maritime Transport (AASTMT) is the largest educational institution in New Alamein City, Egypt – with focus areas …

15 September 2024
University Hospital Jena, Germany
The Centre for Dental, Oral and Maxillofacial Medicine (ZZMK) at the University Hospital Jena has upgraded its training centre with the alphadidact® Digital …

1 February 2024
American University of Iraq Sulaimani, Iraq
The American University of Iraq, Sulaimani (AUIS) was founded in 2006 and has been offering US-style higher education since 2007. With over 1,400 students, it …

2 July 2022
Nova Southeastern University, USA
The Nova Southeastern University (NSU) is listed in Forbes' “America's Top Colleges” ranking – with over 22,000 students and more than 200,000 alumni. In July …

12 September 2021
College of Dentistry, Qatar University, Qatar
In September 2021, the College of Dentistry at Qatar University opened the country's most advanced dental simulation lab. 32 simulation stations are used to …
Next step
Going through the planning together
A first layout needs the floor plan and the number of phantom head workstations planned. From those come the system layout, the cable list and a quotation; coordination with the manufacturer of the treatment units runs in parallel.
EBS Euchner, Heusenstamm near Frankfurt — manufactured in house since 1984, three years of warranty, extendable to five years.